Skip to content

Diagnostics

A diagnostic is a field that is not part of the model state, and cannot affect it: it is computed from the state, usually only to be written to file. Diagnostics are created by output streams, from the names users request (see the user guide), and are computed by the stream before it writes. All diagnostics derive from AbstractDiagnostic, in src/share/diagnostics/abstract_diagnostic.hpp.

Lifecycle

A diagnostic goes through these steps:

  • constructor: it receives a communicator, a parameter list and the grid. All diagnostics are created by a factory, so the signature must be exactly that of the base class. The constructor fills m_field_in_names with the names of the input fields.
  • set_input_field: the customer (e.g., an output stream) sets each input field.
  • initialize: called once all inputs are set. It calls initialize_impl, where the diagnostic can do any setup that needs the inputs (e.g., read their layout). When it returns, the output fields must be allocated.
  • init_timestep: optional, called at the start of each step (e.g., FieldPrev copies its input here).
  • compute: calls compute_impl, unless the inputs and the time stamp are the same as at the last call. Once compute_impl returns, every output gets the time stamp of the evaluation.
  • get: returns the output field. It is allocated once, and reused at every step.

Registration and names

A diagnostic class is registered in the DiagnosticFactory, in src/share/diagnostics/register_diagnostics.hpp:

diag_factory.register_product("WaterPath",&create_diagnostic<WaterPath>);

Output streams map a requested name to a diagnostic in create_diagnostic (src/share/io/eamxx_io_utils.cpp):

  • an expression, such as T_mid.interp(p_mid=500,units='hPa'), is lowered onto one of the diagnostics above (see src/share/io/eamxx_dexpr_diags.cpp);
  • a name in the named_variants table selects a class, and possibly a parameter (e.g., LiqWaterPath is WaterPath with water_kind=Liq);
  • any other name is taken as the name of a registered class.

A diagnostic with one output

Most diagnostics compute one field, which they declare with add_output, in the constructor if its layout is known there, or else in initialize_impl:

WaterPath::
WaterPath (const ekat::Comm& comm, const ekat::ParameterList& params,
           const std::shared_ptr<const AbstractGrid>& grid)
 : AbstractDiagnostic(comm,params,grid)
{
  // ... set m_qname from params ...
  m_field_in_names.push_back("pseudo_density");
  m_field_in_names.push_back(m_qname);

  add_output(m_kind + name(), m_grid->get_2d_scalar_layout(), kg/m2);
}

add_output comes in three forms:

  • add_output(name, layout, units, data_type) creates and allocates the field on the diagnostic grid (units default to none, the data type to Real);
  • add_output(fid) does the same from a FieldIdentifier;
  • add_output(field) takes a field built by the diagnostic (e.g., an alias of an input, or a field whose allocation properties must be set before it is allocated); it must be allocated by the time initialize_impl returns.

Each returns a reference to the stored output, which stays valid, so the diag may give it a mask, or allocate it, right away. compute_impl reads the inputs from m_fields_in and writes into get(), which customers use too. A Field is a handle, so the copy that get() returns shares data, header and mask with the output.

A customer may also set the parameter output_field_name, in which case initialize renames the output to that name (e.g., the dexpr lowering names the output of an expression after the expression). The renamed field is an alias of the original, so it shares data, time stamp, and mask (whose name does not change).

A diagnostic with several outputs

Some diagnostics compute several fields at once, e.g. because they share inputs and loops. NumberPath computes the liquid, ice and rain number paths in one kernel. Such a diagnostic declares each output with add_output, in the constructor:

NumberPath::
NumberPath (const ekat::Comm& comm, const ekat::ParameterList& params,
            const std::shared_ptr<const AbstractGrid>& grid)
 : AbstractDiagnostic(comm,params,grid)
{
  m_field_in_names = {"pseudo_density","qc","nc","qi","ni","qr","nr"};

  auto create = [&](const std::string& kind) {
    return add_output(kind + name(), m_grid->get_2d_scalar_layout(), kg/(kg*m2));
  };
  m_liq  = create("Liq");
  m_ice  = create("Ice");
  m_rain = create("Rain");
}

The rules for such a diagnostic are:

  • all outputs must be declared in the constructor: an output stream stores a new diagnostic under all its output names right after construction, before it can initialize it (initialization waits until the inputs exist), so that a request of another output finds the same instance (see below);
  • each output must be on the diagnostic grid, have a name that no other output has (case insensitive), and be allocated by the end of initialize_impl;
  • get() errors out: keep a handle to each output for compute_impl, as NumberPath does; customers use get(name) (case insensitive), or get_outputs(), a map from name to output;
  • the outputs cannot be renamed via output_field_name. Users who want an output under another name write <name> := <output>;
  • one compute evaluates all outputs, and stamps them all.

The inputs are those of all outputs together: a stream that requests only LiqNumberPath still needs qi, ni, qr and nr, and still computes the ice and rain paths.

get_outputs() is complete right after construction for a diagnostic with several outputs. For a diagnostic with one output, it may be empty until initialize is called.

To expose the outputs to users, add each name to the named_variants table in create_diagnostic, mapped to the class (with no parameter). create_diagnostic returns the class for any of the names, and the stream picks the output by name.

How output streams use diagnostics

An output stream keeps the diagnostics it creates in a static repo, keyed by name, so that two streams requesting the same field share one instance, which is computed at most once per step (an instant stream evaluates its diagnostics on output steps only). A diagnostic with several outputs is stored under each output name, when the first of them is requested. Hence, requesting LiqNumberPath in one stream and IceNumberPath in another gives one NumberPath, which computes all three paths in one evaluation.

Each request adds only its own output to the stream. An output that is not requested is computed, but is not written, and does not affect the stream.

Masks and valid counts

An output may have a valid mask (see Fields). An AVERAGE, MAX or MIN stream then counts, at each entry, the steps where the output is valid (and an AVERAGE stream divides by that count). The count is named after the mask, nvalid_<mask> (a trailing _valid_mask or _mask dropped), and the fields whose masks share a name share the count:

  • a mask created with create_valid_mask() is named <output>_valid_mask, so its output gets a count of its own, nvalid_<output>;
  • a mask with any other name says where a condition holds (e.g., FieldAtPressureLevel names it after the pressure level), and all fields with a mask of that name share one count.

So outputs of one diagnostic can share a count by sharing a mask:

m_a.create_valid_mask("my_region_mask");
m_z.set_valid_mask(m_a.get_valid_mask());

Masks with the same name must hold the same values, since the stream updates the count once, and the horizontal remapper remaps such masks once; sharing the mask, as above, is the way to ensure it. An output that may contain fill values must also call set_may_be_filled(true) on its header.

Testing

  • src/share/diagnostics/tests/multi_output_test.cpp shows how to test a diagnostic directly: create it, set its inputs, initialize, compute, and check each output.
  • src/share/io/tests/io_multi_output_diags.cpp shows how to test a diagnostic through output streams: it registers a test diagnostic in the factory, writes INSTANT and AVERAGE files and reads them back, and inspects the diagnostics of a stream with a class that derives from AtmosphereOutput.
  • src/share/io/tests/io_diags.cpp does the same for a diagnostic with one output.

Converting a diagnostic to several outputs